Description
The PTS sample holder system is a transferrable sample holder for flexible surface analysis and sample preparation. It is capable of both heating and cooling the sample and can be configured with many other features depending upon the particular application. The basic holder has a thermal heat shield, cooling connection and six electrical contacts.
Key features:
■ different heating methods,
■ detachable contacts for heating,
■ detachable cooling.
Technical data
Type |
Heating
methods |
Heating
temp. |
Cooling
temp. |
Thermocouple |
Table
material |
Options / features |
standard |
without heating & cooling |
|
|
|
|
Ti |
▪ BIAS
▪ 4 additional contacts* |
with heating & cooling |
resistive
resistive
EB
resistive
EB | direct
EB |
600 °C
800 °C
900 °C
1000 °C
1200 °C
2000 °C |
100 K
100 K
90 K
100 K
90 K
|
K
K
K
K
K
C |
Cu
SS
Cu
Mo
Mo
|
▪ BIAS
▪ 4 additional contacts*
▪ suitable to work with agressive gases |
dedicated |
for high pressure reactor |
resistive |
700 °C |
183 K |
C/K |
Ti, SS, Alloy C-276, SS covered with Au |
▪ suitable to work with reactive gases
▪ up to 20 bar
▪ for powder samples |
for cleaver |
resistive |
600 °C
(1000°C
on request) |
100 K |
K |
Cu |
▪ sample size: 5×5 mm, min. height 6 mm
▪ Isolated table |
for SPM applications |
direct
resistive
EB
EB |
600 °C
1200 °C
2000 °C |
100 K
100 K
100 K
|
C/K |
Mo covered with
NiT |
▪ TIP Carrier
▪ CANTI Carrier
▪ sample cleaving |
for IR spectrometer |
resistive |
600 °C
1000 °C |
100 K |
K |
Ti, Mo, Cu |
|
others |
for powder samples |
resistive |
1000 °C |
|
K |
Mo, SS |
▪ no heating (Ti, SS) |
with quartz balance |
|
|
|
|
SS |
▪ for deposition applications
▪ quartz size: Ø 14 mm, thickness 0.28 mm |
with Faraday cup |
|
|
|
|
Ti, Mo |
▪ additional potential
▪ different masks |
for 1” – 2” targets |
|
|
|
|
Ti, SS |
▪ for PLD applications (various types of
target: cuboid, irregular shape) |
customized |
|
|
|
|
|
▪ with Peltier module |
adapters for
flag sample
holders |
without heating & cooling |
|
|
|
|
Ti |
▪ left or right side
▪ for 1 or 2 flag sample holders |
with resistive heating
and cooling |
resistive |
1000 °C |
100 K |
K |
Mo |
▪ left or right side |
with EB heating
and cooling |
EB |
2000 °C |
100 K |
C/K |
Mo |
▪ left or right side |
with direct/resistive heating and cooling |
direct
resistive |
1000 °C |
100 K |
K |
Mo |
▪ left, right or front side |
dedicated for laser
heating customized |
laser |
1000 °C |
|
K |
|
▪ left side* |
customized |
|
|
|
|
|
▪ with additionial contacts
▪ for 1 or 2 flag sample holders |
* require dedicated stage